Infrared thermometer operates in 250degC without cooling
Posted to News on 10th Jul 2008, 20:38

Infrared thermometer operates in 250degC without cooling

Micro-Epsilon is launching what it claims is a unique infrared thermometer for use in high-temperature production lines and process environments, enabling the temperature of materials such as fabric and web to be measured in ambient temperatures of up to 250degC without any need for cooling.

Infrared thermometer operates in 250degC without cooling

The non-contact sensor opens up a diverse range of new applications and markets. The Optris CT hot is said to represent a leap forward in its sensor class and enables temperature measurements from -40 up to +975degC in ambient temperatures of up to 250degC without any cooling of the sensor head. This is possible due to several new design features: new detector materials, a new mechanical design and new high-temperature cabling. Micro-Epsilon has used its considerable in-house development capabilities to design new semiconductor electronics and connectors, as well as a more robust, compact sensor housing, that allows the unit to be adapted to suit standard industrial mountings, flanges and brackets.

Potential applications for CT hot include ovens, dryers, heat treatment lines in the metal and glass industries, paper, plastic, textiles and semiconductor manufacturing. In addition, it can be used as part of a control system for drying and finishing processes of textile fabrics, carpet, paper, cardboard, corrugated paper, plasterboard sheets, timber and plastic compounds. Multiple CT hot sensors can be used inside heat treatment lines with several process chambers to measure temperatures of the web or fabric at different points over the length and width. The benefits for the customer are that information can be obtained about the drying curve of the material, moisture content, non-uniform application of coatings and bonding.

In addition, process engineers can optimise energy consumption, speed and product quality by reducing the process temperature once the product is at its desired temperature. The narrow-beam optics on the CT hot enables oblique aiming, which means customers can measure thick fabrics or light fabrics (eg curtains) using the same sensor without any calibration adjustment.

Restricted space

The latest heat treatment lines, for example, are often built inside a machine in a very compact design, in order to optimise process efficiencies. In these applications, sighting tubes for temperature sensors can no longer be positioned outside the process chamber. Compact, non-contact, infrared sensors are therefore required inside the chamber itself. The CT hot with a compact head and no requirement for additional cooling, fits easily into restricted spaces.

Ulrich Kienitz, General Manager at Micro-Epsilon Optris, comments: "In textile or fabric drying processes, for example, companies can position multiple CT hot sensors along the inside of an oven or drying machine, which is typically around 30m in length. The sensors are able to monitor the temperature of a complete sheet or strip of fabric. By analysing the data from the sensors and looking for unusually high temperature gradients and fluctuations, operators can gauge the humidity of the material and change the process operating conditions such as speed."

Competing sensors on the market generally use a much lower optical resolution. The CT hot offers selectable 10:1 and 2:1 optics; most competing sensors use 1:1 or less. The CT hot is also claimed to have a faster response time (30ms) compared to other sensors on the market, which typically offer response times in seconds. Having a smaller head size is another key advantage for the CT hot when it comes to installing the sensors inside restricted spaces.

A key advantage of the CT hot sensor over competing sensors is that it measures temperature of materials at an oblique angle, around 20 to 30 degrees to the material. As Kienitz explains: "No re-calibration adjustment for the emissivity of different fabrics or materials is necessary. By viewing different thicknesses of material at a angle rather than head on, the CT hot sensor creates a homogenous emissivity area to be measured, which makes temperature measurements faster, more reliable and more accurate."

For more information on Micro-Epsilon's CT hot range of non-contact infrared thermometers, email [email protected].


Micro Epsilon UK Limited

No. 1 Shorelines Building
Shore Road
CH41 1AU
UNITED KINGDOM

+44 (0)151 355 6070

Bosch Rexroth ABSSAC Ltd Pilz Automation Ltd Mechan Controls Ltd SICK (UK) LTD Procter Machine Safety M Buttkereit Ltd Micro Epsilon UK Limited Heidenhain (GB) Ltd AutomateUK Kawasaki Robotics (UK) Ltd Servo Components & Systems Ltd Murrelektronik Ltd Rittal Ltd Smartscan Ltd Dold Industries Ltd Leuze electronic Ltd Phoenix Contact Ltd Euchner (UK) Aerotech Ltd AutomateUK STOBER Drives Ltd WEG (UK) Ltd Machinesafe Compliance Ltd HARTING Ltd Spelsberg Els UK Ltd FATH Components Ltd PI (Physik Instrumente) Ltd