Do PLe applications need two interlocks?
Posted to News on 7th Mar 2014, 15:30

Do PLe applications need two interlocks?

Rob Lewis, the Managing Director of Fortress Interlocks, looks at interlock redundancy in PLe machine safety applications.

Do PLe applications need two interlocks?

There is a lot of interest in whether redundancy is required when it comes to interlock actuators. This debate has been on"going for many years but really gained momentum in 2012 by the inclusion of a note in table D8 in ISO 13849"2"2012:

For PLe a fault exclusion for mechanical (eg the mechanical link between actuator and contact element) and electrical aspects is not allowed. In this case redundancy is necessary.

Now that EN ISO 14119 (The Interlock standard) has been published it adds to the debate with the following two paragraphs in section 8 with relation to 'Assessments of faults' and 'Fault Exclusions'.

Where an interlock system requires PLr e... In order to achieve this it is normally not justifiable to exclude faults, such as broken actuators.

There should be a proper selection of the device ensuring that the holding force (Fzh - see 5.7.4) of the guard locking device is sufficient... In this case the use of fault exclusion for breakage of the locking element does not necessarily limit the PL or SIL for the guard locking function.

Clearly there is variability in what the standards say about fault exclusions, with statements ranging from 'not allowed' through 'normally not justifiable' to 'not necessarily limit'; however, the common thread is that actuators breaking must be considered very carefully for PLe applications.

With a typical interlock this is fully understandable, as it is not uncommon for typical actuators to break, leaving the interlock in a fail"to"danger condition. When designing the Fortress amGard Pro Heads and Actuators the objective was to create an indestructible product to meet the interlock standard. With all load-bearing components manufactured from over"dimensioned cast stainless steel, Fortress has constructed an actuator that absorbs more than 50 times the energy of a typical actuator and a head that remains attached beyond 4000kg of load. The end result is a unit with strength beyond that of the hinges, fittings and the guarding itself.

It is the over"dimensioning, rigorous testing and data from 3billion hours of in"service use that gives Fortress and TUV SUD the evidence to state the amGard Pro can be used as a PLe interlock without the use of a secondary interlock.

For PLe applications careful consideration must be given to the actuator. If a normal pressed actuator is to be used then, in all but the lightest-duty applications, a secondary interlock should be used. Alternatively, an interlock that incorporates an actuator and a separate non"contact sensor could be used. However, a Fortress amGard Pro interlock, with its actuator that is stronger than the rest of the guarding, provides the simplest option to achieving a PLe rating.

Follow the link for more information about Fortress amGard Pro interlocks.


Fortress Safety

2 Inverclyde Drive
WV4 6FB
UNITED KINGDOM

+44 (0)1902 349000

Bosch Rexroth ABSSAC Ltd Mechan Controls Ltd SICK (UK) LTD Pilz Automation Ltd Procter Machine Safety Aerotech Ltd Spelsberg Els UK Ltd Phoenix Contact Ltd Murrelektronik Ltd PI (Physik Instrumente) Ltd Servo Components & Systems Ltd STOBER Drives Ltd Dold Industries Ltd Smartscan Ltd Rittal Ltd Machinesafe Compliance Ltd AutomateUK Heidenhain (GB) Ltd HARTING Ltd Leuze electronic Ltd Micro Epsilon UK Limited AutomateUK Kawasaki Robotics (UK) Ltd Euchner (UK) WEG (UK) Ltd FATH Components Ltd M Buttkereit Ltd