New hexapods achieve micron and nanometre accuracy
Posted to News on 29th Apr 2014, 11:48

New hexapods achieve micron and nanometre accuracy

The latest generation of parallel kinematic positioning systems (hexapods) present a dramatic improvement in the design of robotic positional devices that require extreme high accuracy in the micron and nanometre level. By Jim McMahon.

New hexapods achieve micron and nanometre accuracy

Hexapods were initially introduced to public attention in the late 1800s and first employed in an industrial application in the late 1940s, used on a tyre testing machine. Six-axes parallel kinematic positioning systems (hexapods) used in robotics assembly cells debuted in 1954. Since then, with the advent of improved technologies in robotics, servo-motors, and control systems, parallel manipulators have been under continual evolution. Within the past decade, thanks to advances in computer programming capabilities, hexapods have taken a major step forward with increased accuracy and precision. But in the past several years, with the integration of advances in technologies such as piezo actuators, virtual programmable pivot points and system simulation, hexapod performance has taken a significant leap forward, to the extent that electromechanical and piezoelectric hexapods are now viewed as more efficient and accurate systems compared to serial linkage and hydraulic kinematic positioning systems, including those commonly used on robotic arms. The latest versions of hexapods are capable of delivering unprecedented ultra-precision resolution to as low as 0.03 microns (33nm) of incremental motion, and some can provide velocity of several tens of mm/s, making them a preferred robotics system for industrial testing and positioning, microscopy, semiconductor handling, biotechnology and medical applications

Hexapods

A hexapod, also known as a Stewart platform or Gough/Stewart platform, is a six-legged parallel mechanism structure. In it most common form, it consists of two platforms, one fixed and the other movable, which are connected and supported by six actuator legs (struts) that expand and contract, acting in parallel between the platforms. Co-ordinated motion of these six struts enables the movable platform - and devices mounted to it - to move in any direction, operating with six degrees of freedom (DOF) relative to the base platform. With six DOF the movable platform is capable of moving in the three linear directions (x, y and z - lateral, longitudinal and vertical) and the three angular directions (pitch, roll and yaw) singularly or in any combination. Because hexapods have all six degrees of freedom, they can perform manipulations that cannot be done with any other traditional motion system.

In addition to the variable strut length hexapod of the Gough/Stewart flavor, other designs with fixed strut length are also available.

Most hexapod struts are equipped with cardanic joints. Flexure joints provide the highest precision and are completely free of backlash. However, load capacity and travel range are rather small compared to cardanic or sphere joints.

Cardanic joints with Z-offset provide the best load characteristics. These joints are much stiffer than gimbal-type joints; however, they require more sophisticated control algorithms to take into account the complex geometry of each actuator.

Hexapods come in many configurations and sizes, capable of handling loads from a few pounds to more than two tons.

Advanced designs include servo-motor-driven systems for moving large optics or mirrors, piezo-based units for nanometre precision control of processes, and non-magnetic and vacuum-compatible versions. While most hexapods have a cylindrical shape, square or rectangular versions have also been used.

Hexapods have tremendous potential for streamlining many manufacturing processes by improving accuracy and speed, and reducing set-up and processing time.

Hexapods versus serial kinematic positioning systems

Parallel-kinematic mechanism (PKM) motion systems have a number of advantages over standard serial kinematic (stacked) positioning systems. It is easy to see most benefits by just looking at the basic designs.

a) Elimination of cumulative error

In serial kinematic positioning systems, wobble and guiding errors in the bearings of each axis accumulate - the bottom stage supports its

own moving platform plus all stages above it. Each actuator is assigned to one degree of freedom. Integrated position sensors assigned to each drive, measure only the motion caused by that drive and in its direction of motion. All undesired motion (guiding error) in the other five degrees of freedom are not seen and therefore cannot be corrected in the servo-loop, which leads to cumulative error.

b) Less deviation

In a hexapod, all actuators act directly on the same moving platform, with the same dynamic behavior occurring for the six axes. Because each actuator basically only has one degree of freedom (unlike a serial stack of stages, where the bearings in each axis also contribute to crosstalk and runout), runout and accumulation of off-axis errors is much less of a concern for hexapod designs. A hexapod can also be designed much stiffer, so load-shift induced flex is far less of an issue. The results are significantly reduced deviation and improved repeatability.

c) Automatic strut compensation for velocity and vector

As different from serial multi-axis positioning, hexapods require that all six struts alter their lengths if a change in only one axis is intended to occur. However, this is completely transparent to the user. The hexapod controller automatically runs the required co-ordinate transformations directing individual velocity and vector adjustments and transmits new positions to each of the six actuators hundreds of times per second.

d) Reduced parts count

Compared with serial multi-axes systems, hexapods have one-third the number of parts, which means lighter weight and lower friction. Friction and torque in serial systems, caused by as many as five moving cables (cable management), limit accuracy and repeatability.

e) Reduced settling times

Because of the low mass of the moving platform on hexapods, positioning operations can be performed with far lower settling times than with conventional, stacked multi-axes systems.

f) High nominal load-to-weight ratio

The high nominal load-to-weight ratio is a very important advantage of the hexapod over stacked systems. The weight of a load in the hexapod platform is approximately equally distributed on the six parallel legs. This means each link carries only one-sixth of the total weight. Additionally, under certain loads the legs on the hexapod act longitudinally, exerting either tension or compression on the struts - and thereby reducing axial forces.

g) Free access to the work zone

Hexapods allow free access to the work zone, so there is nothing to impede the motion of the machining tool on the workpiece.

h) Large, central aperture

A large central aperture can be critical for optical applications, thru-light applications or those where access to the back of a workpiece is required.

New features support sub-micron ultra-precision

The latest high-resolution hexapod systems are being designed with high-efficiency precision-controlled servo-motors and piezoelectric actuators. Different drive principles are being employed, depending on the application.

For example, new hexapods utilizing Nexline piezoelectric drives from Physik Instrumente - a leading manufacturer of ultra-precision hexapods and piezoelectric motors - make for a positioning device that is completely non-magnetic. Such a system is critical for medical equipment and device applications that require magnetic non-interference. Other uses include high-energy physics applications.

In addition to classical hexapod structures, parallel-kinematic designs are also beneficial to sub-nanometre precise positioning mechanisms, required for AFM (atomic force microscopy) applications and other novel super-resolution microscopy systems. With the integration of non-contact capacitive sensors, run-out errors on a nanometre and sub-nanometre scale can be determined. The sensors continually measure the actual position against the stationary external reference, and a servo-controller can compensate the error in realtime (active trajectory control). Resolution and repeatability can attain 0.1nm in such systems.

Recent hexapod designs provide extremely high stiffness and rigidity of their components and all moving parts, such as its bearings, joints and drive screws. This results in high natural frequencies - 500Hz at a 10kg (22 lbs) load - which prevents bending in the six struts or in the movable platform, making these new hexapods capable of extreme accuracy, and a very useful tool for precision machining, metrology, microscopy and medical applications.

Image
One such system is the new miniature six-axes hexapod, Parallel Kinematics Hexapod Nano-Alignment System from Physik Instrumente (picture here), which can deliver more than 40N (10 lbs) of force and motion in all six degrees of freedom. Minimum incremental motion (real-world motion) is as low as 0.2 microns with actuator resolution of 40nm and travel ranges to 40mm linear and 60 degrees (rotation), and a velocity of 10mm/s. This unit can be used for manufacturing and part placement, alignment of optical components and lasers, microscopy applications and neuroscience that requires high precision. A higher-resolution version (33nm) with reduced load capacity is also available.

The system's high level of accuracy is due to a combination of extremely precise parts, precision assembly and testing, and sophisticated algorithms built into its high-speed controller that take into account the exact tolerances of each strut and joint, and provide precise co-ordinates to each of the six actuators.

Hexapods require the definition of a fixed pivot point as the centre of rotation. Advanced hexapod designs make use of a virtual programmable pivot point for rotational alignment tasks, allowing motion around any point, not unlike the human hand.

Because of the complex motion a hexapod can perform, it is desirable to have simulation tools to explore the possible motion range of the payload mounted to the hexapod. The shape and size of the payload can be added by the user inside or outside the hexapod envelope and the software calculates the distance to any obstacle in its way.

Digital controllers for hexapods

The latest PC-based digital controllers, facilitated by open-interface architecture providing a variety of high-level commands, allow choosing any point in space as the pivot point for the rotation axes by software command. Target positions in six-space are specified in Cartesian co-ordinates, and the controller transforms them into the required motion-vectors for the individual actuator drives. Any position and any orientation can be entered directly and the specified target will be reached by a smooth vector motion. The pivot point then remains fixed relative to the platform.

In addition to the co-ordinated output of the six hexapod axes, these new hexapod controllers provide two additional axes that can be used to operate rotary stages, linear stages or linear actuators. Some include a macro language for programming and storing command sequences.

These controllers feature flexible interfaces, such as TCP/IP interface for remote, network and Internet connection.

Image
New simulation tools are being incorporated for graphical configuration and simulation of hexapods to verify workspace requirements and loads. Such software provides full functionality for creation, modelling, simulation, rendering and playback of hexapod configurations to predict and avoid interference with possible obstacles in the workspace.

With the new design developments that hexapod systems are experiencing, manufacturers and researchers that have a need for extreme high resolutions and high accuracy can now capitalize on them for improvements within their workplace.

Hexapod technology has advanced considerably in a few short years, and now it is up to industry to embrace these new developments and put them to work to reduce their set-up and processing time, overall production cycle times, and ultimately reduced cost of operation.

Follow the link for more information about state-of-the-art hexapods from PI (Physik Instrumente).


PI (Physik Instrumente) Ltd

Trent House, University Way
Cranfield Technology Park
MK43 0AN
UNITED KINGDOM

+44 (0)1234 756360

Bosch Rexroth Pilz Automation Ltd Procter Machine Safety SICK (UK) LTD ABSSAC Ltd Mechan Controls Ltd AutomateUK Aerotech Ltd AutomateUK Murrelektronik Ltd Micro Epsilon UK Limited Spelsberg Els UK Ltd Servo Components & Systems Ltd WEG (UK) Ltd Heidenhain (GB) Ltd Phoenix Contact Ltd Kawasaki Robotics (UK) Ltd Leuze electronic Ltd Machinesafe Compliance Ltd PI (Physik Instrumente) Ltd Smartscan Ltd Dold Industries Ltd FATH Components Ltd STOBER Drives Ltd HARTING Ltd Rittal Ltd M Buttkereit Ltd Euchner (UK)