Viral epidemics such as the current coronavirus (COVID-19) have created a global demand for infrared cameras that are able to screen for a fever condition in humans. Many businesses wish to protect their most important assets, their people, by installing appropriate fever-screening systems. Micro-Epsilon has responded to this demand by introducing an infrared camera specifically for this application.

Thermal imaging camera for measuring human temperature

The new thermoIMAGER TIM QVGA-HD-T100 infrared camera is supplied with a certificate of calibration that validates temperature measurements made against a traceable 35degC temperature reference source (black body). The camera is accurate to +/- 0.5degC when used with the TM-BR20AR-TIM black body source, which means it can provide reliable skin temperature measurements for fever detection systems. It is suitable for integration into an automated monitoring system which can be used in real time at point-of-entry into establishments such as factories, offices, public buildings, warehouses, airports and schools, to prevent people with elevated body temperatures entering.

Glenn Wedgbrow, Business Development Manager at Micro-Epsilon UK comments: "The basis for the effectiveness of thermal cameras as a fever screening tool lies in the correlation of outside skin surface temperature with that of the internal or core body temperature. As a supplier of thermal imaging cameras, we are fielding many questions from existing and prospective customers with regards to their use as a screening tool for COVID-19. Although our cameras do not detect any specific virus or condition, they can be used to detect elevated body temperatures in humans, which may indicate a possible fever."

In crowd-based screening, an infrared camera monitors a crowd of people simultaneously or sequentially. Assuming that the majority of the measured maximum head temperature values are coming from healthy individuals, the exceptions with an elevated body temperature can be detected by the camera.

Individual screening is primarily used at controlled entrances and security gates. The Medial Canthus (tear duct) provides the strongest correlation between outside skin temperature and core body temperature and is measured more precisely from a close distance. This method is also best for detecting low-grade fevers. For this application, Micro-Epsilon recommends the thermoIMAGER TIM QVGA-HD-T100 infrared camera with 29 degree optics placed at a distance of 1m from the target, or the same camera but with 13 degree optics at a distance of 1.5 to 2m from the target. To achieve an accuracy better than +/- 0.5degC the imager must be combined with the TM-BR20AR-TIM Black Body Reference Source.

Absolute temperature measurement accuracy

Most infrared cameras with 8-14um spectral response are specified with an accuracy of +/- 2degC or 2 per cent of the reading, whichever is greater based on deployments in industrial environments in a wide variety of ambient conditions from 0degC to +50degC. This means that many thermal imagers are unable to achieve the accuracy required to detect a fever and so give false positive readings.

Many infrared cameras are being promoted today that claim to offer accuracies of +/- 0.5degC or better. However, these accuracies cannot be achieved without the use of a black body reference source. This source needs to be stable, have high emissivity and should be positioned in close proximity to the person to be scanned. It is vital to select a black body source with a very high stability, as not all black body sources are stable enough to provide a +/- 0.5degC system accuracy.

The TM-BR20AR-TIM ambient black body reference source from Micro-Epsilon can be combined with the thermoIMAGER TIM QVGA-HD-T100 camera. The black body is equipped with a 16-bit digital temperature sensor with +/- 0.1degC accuracy. By integrating this highly accurate reference signal to the TIM Connect software (freely provided with the camera), Micro-Epsilon can reduce camera uncertainties resulting from device adjustment, ambient temperature drift and short term stability down to a system accuracy of +/- 0.5degC with a confidence interval of 95 per cent.

Glenn Wedgbrow adds: "Our thermoIMAGER TIM QVGA-HD-T100 infrared camera combined with our TM-BR20AR-TIM black body reference source provides a highly accurate, reliable non-contact body temperature measurement system that meets the accuracy requirement of EC 80601-2-59:2017 for human fever detection using infrared temperature measurement."

For more information on the thermoIMAGER TIM QVGA-HD-T100 go to www.micro-epsilon.co.uk.


Micro Epsilon UK Limited

No. 1 Shorelines Building
Shore Road
CH41 1AU
UNITED KINGDOM

+44 (0)151 355 6070

Bosch Rexroth ABSSAC Ltd Pilz Automation Ltd Procter Machine Safety Mechan Controls Ltd SICK (UK) LTD Aerotech Ltd Servo Components & Systems Ltd Euchner (UK) M Buttkereit Ltd STOBER Drives Ltd Machinesafe Compliance Ltd Rittal Ltd Micro Epsilon UK Limited FATH Components Ltd Leuze electronic Ltd PI (Physik Instrumente) Ltd Smartscan Ltd Dold Industries Ltd AutomateUK Spelsberg Els UK Ltd WEG (UK) Ltd AutomateUK Kawasaki Robotics (UK) Ltd HARTING Ltd Phoenix Contact Ltd Heidenhain (GB) Ltd Murrelektronik Ltd