Thermal imaging identifies freezer insulation faults
Posted to News on 27th Jun 2019, 14:09

Thermal imaging identifies freezer insulation faults

As important as they are for storing quantities of foodstuffs, commercial walk-in freezers use a lot of energy. So, it is imperative that this consumption is kept to a minimum by ensuring the temperature inside the freezer is not compromised by any breach in the freezer's insulation.

Thermal imaging identifies freezer insulation faults

Thermal imaging is proving a useful technology for this purpose, and the process is much the same as seeking out faults in building fabric. The only difference is the direction of heat. When inspecting a building a thermographer will generally look for heat leaking from the inside of the structure to the outside. But with refrigeration units, the main requirement is to detect heat leaking inwards.

In many cases the problem lies with faulty construction so even the operating costs of new freezers can be unnecessarily high. Frequently joints between the insulation panels are not protected adequately, creating heat bridges. In older units insulation faults are common due to wear but in both cases thermal imaging can see the problem in an instant. However, the quality of the infrared camera is key to the success of this application.

The Dutch consultancy, Thermografisch en Adviesbureau, is frequently commissioned to conduct thermal inspection of commercial freezers and its spokesman explains: "Thermal sensitivity, accuracy and resolution are crucial to the accurate detection of thermal bridges. You need to be able to interpret what you see in a thermal image and if you are using a thermal imaging camera that is below 640 × 480 pixels then you are missing information that you need to draw the right conclusions."

The most sophisticated FLIR thermal imaging camera the consultancy uses for its work combines high resolution with 30mK thermal sensitivity and an accuracy of +/-2degC. And another important feature for freezer inspection the company cites is calibration range.

The spokesman says: "Our FLIR camera is calibrated to a minimum temperature of -40degC and this is very important to ensure accuracy temperature measurement. Most freezers are kept at a temperature between -20degC and -30degC. However, some freezers cool their contents down to -50degC or even -60degC and the FLIR camera is still capable of visualising insulation leaks.

"High-quality thermal imaging cameras and good training come at a price but they are definitely worth the money. We have several FLIR cameras that are used for a wide variety of applications from building, industrial maintenance and HVAC system inspection to detecting water ingress in aircraft composite materials. Our cameras are constantly on the move from site to site."

Learn more at www.flir.com.


Teledyne FLIR

2 Kings Hill Avenue
Kings Hill,
ME19 4AQ
UNITED KINGDOM

+44 (0)1732 220011

Bosch Rexroth ABSSAC Ltd Pilz Automation Ltd Procter Machine Safety Mechan Controls Ltd SICK (UK) LTD FATH Components Ltd Aerotech Ltd Phoenix Contact Ltd Servo Components & Systems Ltd STOBER Drives Ltd AutomateUK AutomateUK Spelsberg Els UK Ltd M Buttkereit Ltd WEG (UK) Ltd Heidenhain (GB) Ltd Kawasaki Robotics (UK) Ltd HARTING Ltd Micro Epsilon UK Limited Murrelektronik Ltd Euchner (UK) Leuze electronic Ltd Smartscan Ltd PI (Physik Instrumente) Ltd Machinesafe Compliance Ltd Rittal Ltd Dold Industries Ltd